Zero-Defect Metrology & Certification

Quality & Certifications

Every batch undergoes 14 mandatory quality checks, conforming strictly to ASME BPE, 3-A Sanitary, ASTM, and DIN standards.

Home>Quality
Digital Equipments & Quality Metrology

In-House Digital Testing Equipments

100% calibrated digital metrology instruments deployed to ensure strict ASME BPE, 3-A Sanitary, and DIN dimensional compliance.

Digital Surface Roughness (Ra) Tester
Surface Metrology

Digital Surface Roughness (Ra) Tester

Internal bore surface finish verification for electropolished tubes & fittings

View Details & Specs
Digital Precision Vernier Caliper
Dimensional Inspection

Digital Precision Vernier Caliper

Precision checks on flange OD, tube wall thickness, and weld neck step depths

View Details & Specs
Digital External Calibrated Micrometer
Dimensional Metrology

Digital External Calibrated Micrometer

Critical outer diameter and wall thickness verification for ASME BPE sanitary tubes

View Details & Specs
Heavy-Duty Digital Height Gauge
Height & Layout Metrology

Heavy-Duty Digital Height Gauge

Center-to-face alignment, port perpendicularity, and height tolerance on 90°/45° elbows

View Details & Specs
14
Mandatory Tests
On 100% of Production Batches
Total Quality Management

Our Commitment to Zero-Defect Engineering

At Trisha Fittings, quality is not an afterthought; it is ingrained into our manufacturing DNA. Because our products are trusted in sterile applications across pharmaceutical WFI loops, biotech fermenters, and aseptic dairy pipelines, even a microscopic flaw is intolerable.

That is why every single stainless steel tube and fitting undergoes a comprehensive 14-point testing protocol before leaving our plant. From raw material spectroscopic validation to internal optical profilometer roughness verification, complete batch compliance is guaranteed.

Inspection Protocol

The 14-Step Quality Assurance Process

Stringent destructive and non-destructive testing performed at every stage of the manufacturing cycle.

1

Chemical Composition Analysis

Verifying raw material composition using Optical Emission Spectrometers.

2

Tensile & Yield Test

Evaluating ultimate tensile strength and ductility of the steel under mechanical strain.

3

Hardness Testing

Measuring Rockwell & Brinell hardness to verify proper heat treatment.

4

Flattening Test

Testing tube ductility, cold-formability, and weld seam integrity.

5

Flaring & Expansion Test

Assessing the ability of the tube to be expanded without micro-cracking.

6

Hydrostatic Pressure Test

Pressurizing tubes with water up to 100% test pressure to check structural integrity.

7

Eddy Current Inspection

Continuous in-line non-destructive testing to detect sub-surface material flaws.

8

Ultrasonic Flaw Detection

Using high-frequency sound waves to verify internal acoustic homogeneity.

9

Surface Roughness (Ra Value)

Measuring internal Ra values with diamond profilometers (guaranteed Ra ≤ 0.4 µm).

10

Intergranular Corrosion (IGC)

Testing resistance to localized intergranular attack according to ASTM A262.

11

Dimensional Tolerancing

Precision checks for OD, ID, wall thickness, ovality, and straightness.

12

Microstructure Metallography

Examining grain boundary structure of the austenitic steel under high-magnification.

13

Visual & Boroscopic Inspection

Detailed optical probe check for surface scratches, pits, and weld seams.

14

Positive Material Identification (PMI)

100% XRF spectrometer alloy verification to ensure certified SS 304/316L grades.

International Accreditations & Sanitary Certifications
ISO 9001:2015

ISO Certified

Quality Management System

3-A Sanitary

3-A Compliance

Hygienic Dairy & Food Standards

ASME BPE

ASME BPE

Bioprocessing Equipment Purity

Ra ≤ 0.4 µm

Ra ≤ 0.4 µm

Electropolished Mirror Finish

EN 10204 3.1

3.1 MTC Certified

100% Material Traceability